High Frequency X-Ray & Mammomex
Mammomex 2000
State Of The Art Mammography Machine With Microprocessor Control
Features:
High Frequency
Generator
Output Power : 5kw
Input Power : 180–264vac, Single Phase, 50hz/60hz, 50a Max
Kv : 20 To 40kv With 1kv Step
High Frequency With Kv Closed Loop And Line Feed Forward
Compensation
Inverter Technology 40khz H.F Current Fed, Igbt Bridge With Output Current Limit
Capability And Short Circuit Protection.
Safety Timer 10 S
Generator Control Mode 2 Mode/3 Mode
Starter Dual
Focal Spot Size 0.1 Small 0.3 Large
Target Material Molybdenum
Breast Pressure : 20kg Max
Cassette Size : 10” X 12”
Line Voltage Compensation : Automatic
Increase Or Decrease
Ma : 10 To 140ma
Mas : 0.05 To 500mas
Filament Output : 0 To 6a At A Compliance Of 5.5 Volts, Maximum. Dual Focus
Max. Time : 10s
Starter : Dual Speed, High Speed (150hz / 180hz) And Low Speed (50hz /60hz)
C-Arm With Stand Robust ,Highly Precision Motor Drive For Up And Down And Rotational Movement.
Unit Approved By Aerb And Complies To Standard 93/42/Eec
Mammomex 2000 Is Versatile Mammography Machine Designed For High Volume Diagnostic And Screening Investigations. It Is User Friendly And Simple To Operate.
Mammomex 2000
State Of The Art Mammography Machine With Microprocessor Control
Features:
High Frequency
Generator
Output Power : 5kw
Input Power : 180–264vac, Single Phase, 50hz/60hz, 50a Max
Kv : 20 To 40kv With 1kv Step
High Frequency With Kv Closed Loop And Line Feed Forward
Compensation
Inverter Technology 40khz H.F Current Fed, Igbt Bridge With Output Current Limit
Capability And Short Circuit Protection.
Safety Timer 10 S
Generator Control Mode 2 Mode/3 Mode
Starter Dual
Focal Spot Size 0.1 Small 0.3 Large
Target Material Molybdenum
Breast Pressure : 20kg Max
Cassette Size : 10” X 12”
Line Voltage Compensation : Automatic
Increase Or Decrease
Ma : 10 To 140ma
Mas : 0.05 To 500mas
Filament Output : 0 To 6a At A Compliance Of 5.5 Volts, Maximum. Dual Focus
Max. Time : 10s
Starter : Dual Speed, High Speed (150hz / 180hz) And Low Speed (50hz /60hz)
C-Arm With Stand Robust ,Highly Precision Motor Drive For Up And Down And Rotational Movement.
Unit Approved By Aerb And Complies To Standard 93/42/Eec
Mammomex 2000 Is Versatile Mammography Machine Designed For High Volume Diagnostic And Screening Investigations. It Is User Friendly And Simple To Operate.
ME 8015 High Frequency X-Ray Machine
Features
High Frequency range from 100KHZ to 400 kHz
KW output range 32/40/50/65/80KW
Operating Modes: 3 Point or 2 point technique
Anatomical Programming
Compatible with DR/CR
Radiography and Radiography/ Fluoroscopy operations
Maximum Radiography KVP 150
Self detecting Service Software
ME 8015
Features
High Frequency range from 100KHZ to 400 kHz
KW output range 32/40/50/65/80KW
Operating Modes: 3 Point or 2 point technique
Anatomical Programming
Compatible with DR/CR
Radiography and Radiography/ Fluoroscopy operations
Maximum Radiography KVP 150
Self detecting Service Software
ME 8015 High Frequency X-Ray
Features
High Frequency range from 100KHZ to 400 kHz
KW output range 32/40/50/65/80KW
Operating Modes: 3 Point or 2 point technique
Anatomical Programming
Compatible with DR/CR
Radiography and Radiography/ Fluoroscopy operations
Maximum Radiography KVP 150
Self detecting Service Software
--- mouse over thumbnail to view enlarged image ---
|